Table of Content
A site, building, facility, or portion thereof that complies with this part. NFPA 72 specifies characteristics for visible alarms, such as flash frequency, color, intensity, placement, and synchronization. However, Section 702 of this document requires that visual alarm appliances be permanently installed. UL 1971 specifies intensity dispersion requirements for visible alarms.

Play areas located in family child care facilities where the proprietor actually resides shall not be required to comply with 240. Where only the minimum 50 percent of the holes are accessible, an accessible route from the last accessible hole to the course exit or entrance must not require travel back through other holes. In some cases, this may require an additional accessible route.
CHAPTER 9: BUILT-IN ELEMENTS
Buildings that are vacated solely for pest control or asbestos removal are not subject to the requirements to provide residential dwelling units with mobility features or communication features. Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those not required to be accessible. This applies to all doors, including bathroom doors, that allow full user passage. Other requirements for doors and doorways in Section 404 do not apply to guest rooms not required to provide mobility features.
Interior or exterior circulation paths, rooms, spaces, or elements that are not for public use and are made available for the shared use of two or more people. Each of the lift types addressed in ASME A18.1 must meet requirements for capacity, load, speed, travel, operating devices, and control equipment. The maximum permitted height for operable parts is consistent with Section 308 of this document. The standard also addresses attendant operation. However, Section 410.1 of this document does not permit attendant operation.
CHAPTER 10: RECREATION FACILITIES
Full compliance will be considered structurally impracticable only in those rare circumstances when the unique characteristics of terrain prevent the incorporation of accessibility features. Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access. There are a variety of seats available on pool lifts ranging from sling seats to those that are preformed or molded. Pool lift seats with backs will enable a larger population of persons with disabilities to use the lift.
Ensure that hand-held shower spray units are capable of delivering water pressure substantially equivalent to fixed shower heads. No more than one bowl of a multi-bowl sink shall be required to provide knee and toe clearance complying with 306. If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308.
Construction & Price
Locate soap and towel dispensers so that they are conveniently usable by a person at the accessible lavatory. When the door to the toilet room is placed directly in front of the water closet, the water closet cannot overlap the required maneuvering clearance for the door inside the room. Water Closet Location604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 604.3. Handrail Height505.5 Clearance. Clearance between handrail gripping surfaces and adjacent surfaces shall be 1 1/2 inches minimum.

Play components are manufactured or natural; and are stand-alone or part of a composite play structure. The number of persons for which the means of egress of a building or portion of a building is designed. Employee Work Area. All or any portion of a space used only by employees and used only for work.
We consider our client’s security and privacy very serious. We do not disclose client’s information to third parties. Our records are carefully stored and protected thus cannot be accessed by unauthorized persons. Our payment system is also very secure.
In transfer type shower compartments, thresholds 1/2 inch high maximum shall be beveled, rounded, or vertical. Clearance in front of bathtubs shall extend the length of the bathtub and shall be 30 inches wide minimum. A lavatory complying with 606 shall be permitted at the control end of the clearance. Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches minimum beyond the wall at the head end of the bathtub.
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with 708.4. The technical standards for assistive listening systems describe minimum performance levels for volume, interference, and distortion. Sound pressure levels , expressed in decibels, measure output sound volume.
Risers shall be 4 inches high minimum and 7 inches high maximum. Treads shall be 11 inches deep minimum. 503.2 Vehicle Pull-Up Space.
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches maximum above the finish floor. Door closers and door stops shall be permitted to be 78 inches minimum above the finish floor or ground. An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches maximum. Position of Clear Floor or Ground Space305.6 Approach. One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. 305.2 Floor or Ground Surfaces.